Data Item _ma_qa_metric.type

General

Item name
_ma_qa_metric.type
Category name
ma_qa_metric
Attribute name
type
Required in PDB entries
yes
Used in currrent PDB entries
No

Item Description

The type of QA metric.

Data Type

Data type code
line
Data type detail
char item types / multi-word items ...
Primitive data type code
char
Regular expression
[][ \t_(),.;:"&<>/\{}'`~!@#$%?+=*A-Za-z0-9|^-]*

Controlled Vocabulary

Allowed Value Details
PAE predicted aligned error (in Angstroms)
boolean 0 or 1 depending on whether a check passed (1) or not (0)
contact probability the contact probability of a pairwise interaction
distance the lower the distance, the better the quality
energy the lower the energy, the better the quality
ipTM confidence score of protein-protein interface based on the template modeling score in [0,1]
normalized score normalized score ranging from 0 to 1
other other type of QA metric
pLDDT confidence score predicting accuracy according to the CA-only Local Distance Difference Test (lDDT-CA) in [0,100]
pLDDT all-atom confidence score predicting accuracy according to the all-atom Local Distance Difference Test (lDDT) in [0,100]
pLDDT all-atom in [0,1] confidence score predicting accuracy according to the all-atom Local Distance Difference Test (lDDT) in [0,1]
pLDDT in [0,1] confidence score predicting accuracy according to the CA-only Local Distance Difference Test (lDDT-CA) in [0,1]
pLDDT to polymer confidence score predicting accuracy according to lDDT with distances from each atom to CA or C1' of nearby polymer residues in [0,100]
pTM confidence score predicting accuracy according to the template modeling score in [0,1]
zscore number of standard deviations from optimal/best

Controlled Vocabulary at Deposition

Allowed Value Details
PAE predicted aligned error (in Angstroms)
boolean 0 or 1 depending on whether a check passed (1) or not (0)
contact probability the contact probability of a pairwise interaction
distance the lower the distance, the better the quality
energy the lower the energy, the better the quality
ipTM confidence score of protein-protein interface based on the template modeling score in [0,1]
normalized score normalized score ranging from 0 to 1
other other type of QA metric
pLDDT confidence score predicting accuracy according to the CA-only Local Distance Difference Test (lDDT-CA) in [0,100]
pLDDT all-atom confidence score predicting accuracy according to the all-atom Local Distance Difference Test (lDDT) in [0,100]
pLDDT all-atom in [0,1] confidence score predicting accuracy according to the all-atom Local Distance Difference Test (lDDT) in [0,1]
pLDDT in [0,1] confidence score predicting accuracy according to the CA-only Local Distance Difference Test (lDDT-CA) in [0,1]
pLDDT to polymer confidence score predicting accuracy according to lDDT with distances from each atom to CA or C1' of nearby polymer residues in [0,100]
pTM confidence score predicting accuracy according to the template modeling score in [0,1]
zscore number of standard deviations from optimal/best